Water quality micro-monitoring station

Water quality micro-monitoring station

Model:FT-WMSM
Brand:fengtu
Water quality micro-monitoring station is a kind of small equipment used to monitor water quality, which can meet the online monitoring of urban river water quality....

1. Product introduction of water quality micro monitoring station :

The water quality micro-monitoring station is also called a micro-automatic water quality monitoring station. The water quality micro-monitoring station is a small device used to monitor water quality. It meets the online monitoring of urban river water quality and solves the problem of the large area and infrastructure investment of conventional automatic water quality monitoring stations. Advanced questions. In response to the national strategic policy on strengthening environmental protection, maintaining the balance of natural ecology, and promoting the sustainable development of the national economy, and based on market needs, our company independently developed and produced the outdoor small automatic water quality monitoring station FT-WMSM, which combines the methods stipulated in the national standard with advanced Combining advanced computer technology, the measurement process is fully automated and can be widely used for surface water quality monitoring in rivers and lakes.

The factors causing eutrophication of surface water are mainly chemical factors such as N, P, organic matter, and HN4- in the water body. Therefore, monitoring chemical indicators such as total phosphorus, total nitrogen, ammonia nitrogen, chemical oxygen demand, and permanganate index of surface water has been It has become a necessary task to coordinate with the simultaneous monitoring of five conventional parameters (dissolved oxygen, turbidity, conductivity, temperature, pH) to comprehensively reflect water environment indicators.


2. Monitoring principle of water quality micro-monitoring station:

The water quality micro-monitoring station adopts an integrated design principle and includes a water collection and distribution system, a detection unit (five measurement modules for total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, and five conventional parameters), and a quality control unit. , auxiliary units (waste liquid collection, lightning protection, air conditioning, etc.). The core unit is the detection unit, total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, chemical analysis methods that strictly follow the national standards. Conventional five parameter indicators (dissolved oxygen, conductivity, turbidity, temperature, pH) are measured using multi-electrode integration.


3. Main specifications and standards for water quality micro-monitoring stations:

According to the design documents, equipment, materials and construction must meet the requirements of the current engineering construction standards and specifications of the People's Republic of China and provinces, autonomous regions, municipalities or industries. The technical standards and specifications followed by this project are as follows:

(1) "Technical Specifications for Monitoring Total Water Pollutant Discharge"

(2) "Water and Wastewater Monitoring and Analysis Methods" (Fourth Edition)

(3) "Environmental Water Quality Monitoring Quality Assurance Manual"

(4) "Technical Specifications for Surface Water and Sewage Monitoring" (HJ/T91-2002)

(5) "Technical Guidance on Water Quality River Sampling" (HJ/T52-1999)

(6) "Technical Requirements for Chemical Oxygen Demand Water Quality Automatic Analyzers" (HJ/T377-2007)

(7) "Technical Requirements for Automatic Water Quality Analyzers with Permanganate Index" (HJ/T100-2003)

(8) "Technical Requirements for Automatic Ammonia Nitrogen Water Quality Analyzers" (HJ/T101-2003)

(9) "Technical Requirements for Total Nitrogen Water Quality Automatic Analyzer" (HJ/T 102-2003)

(10) "Technical Requirements for Automatic Total Phosphorus Water Quality Analyzer" (HJ/T 103-2003)

(11) "Technical Requirements for Automatic pH Water Quality Analyzers" (HJ/T96-2003)

(12) "Technical Requirements for Automatic Conductivity Water Quality Analyzers" (HJ/T97-2003)

(13) "Technical Requirements for Automatic Turbidity Water Quality Analyzers" (HJ/T98-2003)

(14) "Technical Requirements for Automatic Dissolved Oxygen (DO) Water Quality Analyzers" (HJ/T99-2003)

(15) Relevant national and industry standards and specifications

(16) "Environmental Protection Industry Standard of the People's Republic of China" (HJ/T98-2003)

(17) "Building Lightning Protection Design Code"

(18) "Design Code for Power Supply and Distribution System"


4. Product features of water quality micro monitoring station:

1. The integrated automatic water quality automatic monitoring station is adopted, which can measure multiple elements at the same time;

2. A variety of analysis and detection units with low detection limits, meeting the requirements for online surface water monitoring;

3. The water collection and distribution unit has water sample pretreatment and backwash functions, low failure rate and easy maintenance;

4. Optional UPS uninterruptible power supply ensures that the water station can complete the cleaning process in the event of a power outage;

5. Optional video surveillance equipment has real-time remote monitoring function and realizes all-round monitoring;

6. It occupies a small area, and the whole machine occupies an area of ≤2m2;

7. Equipped with waste liquid separation and waste liquid collection units.

8. Suitable for the collection of waste liquid for more than two weeks; equipped with lightning protection unit to ensure stable and reliable operation of the system;

9. Intelligent constant temperature system, equipped with cabinet-type heating and cooling air conditioners, ensures that the water station operates at the specified operating temperature.


5. Technical parameters of water quality micro-monitoring station:

projectTotal phosphorus, ammonia nitrogen, total nitrogen, chemical oxygen demand, permanganate index parameter performance indicators
total phosphorusAmmonia nitrogentotal nitrogenCodpermanganate index
Reference standardGB11893-89HJ/536-2009HJ 636-2012HJ828-2017GB11892-89
Measuring range0.02~2mg/L (expandable)0.1~5mg/L (expandable)0.1~10mg/L (expandable)15~2000mg/L (expandable)0.5~20mg/L (expandable)
The detection limit≦0.01mg/L≦0.10mg/L≦0.1mg/L≦15mg/L≦0.1mg/L
drift±5%±5%±5%±5%≦0.5mg/L
Precision≤5%≤5%≤5%≤5%±5%
Indication error±5%±5%±5%±5%≤5%
Voltage effect±10%±5%±10%±5%±5%
Temperature effect±5%±5%±5%±5%±5%
consistency≥90%≥90%≥90%≥90%±5%
The sampling periodTime interval (20~9999min, arbitrarily adjustable) and hourly measurement mode
Calibration periodAdjustable at any time and at any interval from 1 to 99 days
Maintenance cycleUsually once a month, about 60 minutes each time

Conventional five-parameter technical indicators of water quality micro-monitoring station:

Five parameter performance indicators
Measurement methodspHDissolved oxygenConductivityTurbiditytemperature
glass electrode methodFluorescence quenching methodFour-wire electrode method90 degree scattered light methodThermal resistance electrode method
Reference standardGB/T6920-86GB/T11913-89GB/T6908-201GB/T13200-91GB/T13195-91
Measuring range0~140mg/L~20mg/L0ms/m~500ms/m0NTU~1000NTU0~50℃
drift±0.1pH±0.3mg/L±1%±5%——
Precision≤0.1pH≤5%≤1%≤5%——
Indication error±0.1pH≤5%±1%±5%——
Voltage effect±0.1pH≤0.3mg/L±1%±5%——
Temperature compensation accuracy±0.1pH±0.3mg/L±1%————
water temperature error————————±0.2℃
Calibration periodUsually twice a month
Maintenance cycleUsually once a month, about 30 minutes each time

Water quality micro-monitoring station parameters:

Machine parameters
control unitARM9 embedded industrial control system
Display unit15-inch color touch screen control
Temperature Control SystemEquipped with dual-purpose air conditioning
UPS regulated power supply (optional)Optional UPS uninterruptible power supply can complete this measurement and cleaning process in the event of a sudden power outage.
Lightning protection unitWith lightning protection capability
Power requirementsAC 220V±22V, 50Hz±0.5Hz
Communication Interface2 channels RS485, support 4G wireless transmission
Total power≦2500W (including the maximum power when the external pump and air conditioner are working)
ambient temperature(5~40)℃
DimensionsHeight 1900mm×Width 1480mm×Depth 960mm
water station weight300kg


6. Water quality micro-monitoring station configuration list

serial numberproduct namequantity
1Stainless steel outdoor cabinet (including air conditioning)1 set
2Electrical unit (PLC, relay, circuit breaker, switching power supply, lightning protection)1 set
3Display unit (including 15-inch large screen, microcomputer control program)1 set
4Water collection unit (pipe, sampling pump, float)1 set
5Water distribution unit (electric ball valve, pipes)1 set
6Pretreatment unit (flow cell, level sensor, pressure sensor)1 set
7permanganate index1 set
8COD online monitor (optional)1 set
9NH3N online monitor1 set
10TP online monitor1 set
11TN online monitor1 set
12Five parameters (oxygen decomposition, conductivity, turbidity, temperature, pH)1 set
13Digital acquisition instrument1 set
14Chemical reagents (240 times/month) free of charge1 set