Portable soot analyzer

Portable soot analyzer

Model:testo310
Brand:fengtu
Portable soot analyzer is mainly used in special inspection industry, thermal power plant, petrochemical and other industrial combustion equipment and boiler environmental protection and energy saving monitoring services....

1. Product introduction of portable smoke analyzer

Portable smoke analyzers are also called portable smoke analyzers and portable flue exhaust gas detectors. Portable smoke analyzers are mainly used in industrial combustion devices and boilers in special inspection industries, energy conservation supervision centers, thermal power stations, petrochemical industries, scientific research university laboratories, etc. Environmental protection and energy saving monitoring services. Precise readings, robust design, easy operation: these are the basic requirements for a measuring tool as a professional for fast and reliable on-site testing of combustion equipment and analysis of combustion efficiency. And this is the advantage of the testo 310 portable flue gas analyzer.

The testo 310 portable flue gas analyzer provides reliable detection of heating systems

The testo 310 flue gas analyzer is easy to operate and has 4 built-in guided measurement menus: flue gas measurement, extraction force measurement, ambient CO measurement and differential pressure measurement. Large display with backlight, suitable for various lighting conditions.

Not only that, this handheld flue gas analyzer also has many other useful features. The back of the instrument is magnetic and can be attached to all metal surfaces, such as the burner housing, freeing your hands for other tasks. The sensor automatically zeroes in just 30 seconds, and filter replacement is extremely easy. At the same time, the testo 310 is light, strong and durable, dust-proof and impact-proof, and has a built-in condensation channel for quick and easy emptying.

The measurement data can also be directly transmitted to the testo infrared printer (optional) through the built-in infrared interface of the instrument to realize on-site report printing.

Testo 310 probe extension, probe length 254mm, order number 0563 3120.


2. Application scope of portable smoke analyzer

Flue draft measurement

The pumping force measurement is actually a differential pressure measurement. This pressure difference is caused by the temperature difference between the two areas. The pressure difference in turn creates a compensating air flow. In the flue gas system, the difference in pressure is reflected as "flue draft". We can extend the probe through the flue measuring point to the center point of the flue gas flow to measure the pressure difference, which is the "flue draft force".

To ensure that flue gas can be safely discharged from the flue, the boiler system must have a pressure difference (flue suction force).

If the suction force is always very high, the average smoke temperature will rise, resulting in smoke loss and system efficiency will decrease.

If the suction force is always low, there may be a lack of oxygen during the combustion process, resulting in an increase in blackness and CO, which will also reduce system efficiency.

Ambient CO measurement

CO is a colorless and odorless toxic gas. CO is produced when incomplete combustion of carbon-containing substances (such as oil, gas, and solid fuels) occurs. After CO enters the lungs with breathing, it will enter the blood vessels of the human body and synthesize with hemoglobin, causing the human body to be hypoxic, which in turn can lead to human death. This is why it is necessary to regularly measure CO emissions at the combustion point of the combustion system, especially in and around areas frequently visited by people.

Flue gas parameter measurement (CO, O2, temperature, etc.)

Flue gas measurement of the heating system can help users confirm the pollutants (such as carbon monoxide CO) emitted in the flue gas and the heat loss. In some countries, flue gas measurements are required by law for two main purposes:

1. Ensure to reduce pollution emissions as much as possible and protect the environment;

2. And improve energy efficiency as much as possible.

The legal pollutant content and energy loss standards per unit flue gas volume must not be exceeded.

Measurements can be taken by the installer during system commissioning and, if necessary, by flue gas inspectors after four weeks, and then by authorized service engineers at regular intervals.

Pressure measurement (injection pressure, gas pressure, etc.)

During the maintenance of the home heating system, we usually have to check the gas pressure, including dynamic pressure and static pressure. If the gas pressure of the gas boiler exceeds the range of 18-25mbar, it cannot be adjusted and the boiler cannot be operated. Because if the operation is carried out, the boiler will not be able to operate normally, and an explosion will occur after ignition, causing the system to be paralyzed.


3. Product composition of portable smoke analyzer

testo 310 portable flue gas analyzer

Contains rechargeable battery

O2, CO, hPa and ℃ calibration report

180mm flue gas probe with fixed cone

Silicone hose for pressure measurement

10 dust filters and instrument box

Infrared printer and 2 rolls of thermal printing paper


4. Technical parameters of portable smoke analyzer

Product Features 
weight(including probe) about 700 g
size201 x 83 x 44mm
operating temperature-5 ~ +45 °C
Display typeLCD (Liquid Crystal Display)
Display characteristicsBacklit, 2-line display
power supplyRechargeable battery: 1500 mAh, power supply 5V / 1A
Storage temperature-20 ~ +50 °C
Type K (NiCr-Ni) 
Measuring range-20 ~ +100 °C
measurement accuracy±1 °C
resolution0.1°C
Response time t₉₀< 50 s
Temperature (ambient temperature) 
Type J (Fe-CuNi) 
Measuring range0 ~ +400°C
measurement accuracy±1 °C (0 ~ +100 °C)
±1.5 % of measured value (> 100 °C)
resolution0.1°C
Response time t₉₀< 50 s
Temperature (flue gas) 
O₂measurement 
Measuring range0 ~ 21 Vol.%
measurement accuracy±0.2 Vol.%
resolution0.1 Vol.%
Response time t₉₀30 seconds
Pumping force measurement 
Measuring range-20 ~ +20 hPa
measurement accuracy±0.03 hPa (-3.00 ~ +3.00 hPa)
±1.5% of measured value (rest of range)
resolution0.01 hPa
Effectiveness measurement 
Measuring range0~120%
resolution0.001
flue gas loss 
Measuring range0~99.9%
resolution0.001
CO₂ measurement (calculated by O₂) 
Measuring range0 ~ CO₂ max (display range)
measurement accuracy±0.2 Vol.%
resolution0.1 Vol.%
Response time t₉₀< 40 seconds
pressure measurement 
Measuring range-40 ~ +40 hPa
measurement accuracy±0.5 hPa
resolution0.1 hPa
CO measurement (without H₂ compensation) 
Measuring range0 ~ 4000 ppm
measurement accuracy±20 ppm (0 ~ 400 ppm)
±5% of measured value (401 ~ 2000 ppm)
±10% of measured value (2001 ~ 4000 ppm)
resolution1ppm
Response time t₉₀60 seconds
CO environment measurement 
Measuring range0 ~ 4000 ppm
measurement accuracy±20 ppm (0 ~ 400 ppm)
±5% of measured value (401 ~ 2000 ppm)
±10% of measured value (2001 ~ 4000 ppm)
resolution1ppm
Response time t₉₀60 seconds