Doppler Ultrasonic Flow Meter

Doppler Ultrasonic Flow Meter

Model:FT-L3
Brand:fengtu
Doppler Ultrasonic Flow Meter is an integrated non-contact measurement of water level and velocity using Doppler radar K-band technology to detect the surface velocity of water flow....

1. Product introduction of Doppler Ultrasonic Flow Meter

Doppler Ultrasonic Flow Meter is an integrated non-contact measurement of water level and velocity using Doppler radar K-band technology to detect the surface velocity of water flow.Doppler Ultrasonic Flow Meter is mainly composed of a radar flow meter and a radar water level meter. The flow meter is used to collect the fluid surface flow velocity, and calculates the average flow rate of the water cross section through model calculation, and then calculates the flow cross section based on the water level and cross section information measured by the water level meter. area, and then use the formula flow rate = average flow velocity × flow cross-sectional area × correction coefficient to obtain the flow rate, where the correction coefficient is calculated based on the standard value obtained from the actual measurement environment.

2. Technical parameters of Doppler Ultrasonic Flow Meter

parameterillustrate
Supply voltageDC 7~28V
Current (12V power supply)It is about 300mA during normal operation and less than 1mA in sleep mode.
working temperature-35°~70°
Waterproof levelIP67
Transmission frequency24.000~24.250GHz
Communication interfaceRS-232/RS-485
Communication protocolMODBUS-RTU/custom protocol
Speed range0.15~15m/s
Speed measurement accuracy±2%
speed resolution0.01m/s
Ranging range0.4~40m
Ranging accuracy±1cm
distance resolution1mm
Antenna styleFlow rate: 14 x 32゜

Water level: 11 x 11゜

Interval time1~5000min
Flowmeter size (length × width × height)220×120×83.8mm
Bracket size (length × width × height)100×100×100mm
weightFlowmeter + bracket: 5.8kg
Shell materialGalvanized, stainless steel plate

3. Selection of Doppler Ultrasonic Flow Meter measurement channel section

The selection of measuring channel sections is directly related to the accuracy of measuring flow. In order to obtain better measurement results, the measuring channel sections should try to meet the following conditions:

1. There are no huge rocks blocking water in the test channel section, and there are no huge whirlpools, turbulence and other phenomena.

2. The test canal section should be straight, stable, and have concentrated water flow.

3. The test channel section needs to be hardened, and the measurement section should be regular.

4. The test channel section should be kept smooth to prevent accumulation of floating objects.

4. Doppler Ultrasonic Flow Meter installation precautions

1. Install the flow meter, water level meter and flow meter radar without obstruction, otherwise the measurement accuracy will be affected.

2. When installing the flow meter, try to ensure that the upper surface of the housing is level and install it in the middle of the channel.

3. It is recommended that the current meter beam should face the direction of the incoming water, as shown in Figure 3-3, and the horizontal angle to the direction of the water flow should be 0 degrees.

4. The flow meter is only affected by dynamic targets. When the channel is hardened and there are no weeds or trees, even if the beam irradiates both sides of the channel, it will not affect the flow measurement.