Meteorological environment monitoring equipment supplier
Insist on doing high-precision customer favorite technology products
1. Introduction to odor monitoring system
The odor online monitoring system is also called the odor environment online monitoring system. The odor online monitoring system is specially developed for places that cause odor substances and harmful gases. It can conduct real-time measurement of gases containing NH3, H2S, TVOC and dimensionless odor concentration OU values. Online Monitoring. The FT-EC04 odor online monitoring system is based on our company's many years of experience in gas detection and atmospheric environment monitoring. In accordance with the "Odor Pollutant Emission Standard (GB14554-1993)" and "Odor Pollution Environmental Monitoring Technical Specifications (HJ905-2017)", it is specially designed for easy For places where odor occurs, an online monitoring system for odor concentration is independently developed and produced, commonly known as the odor electronic nose;
The concept of stench:
Odor refers to all gaseous substances that stimulate the olfactory organs, cause people's discomfort and damage the living environment. There are many types of them. So far, there are more than 4,000 types that can be sensed by the human sense of smell, among which dozens of types are more harmful to human health. ;
Scenes where the stench appears:
Science and technology parks, chemical parks, landfills, garbage treatment stations, waste power plants, waste incineration sites, chemical plants, breeding farms, sewage treatment plants, pharmaceutical factories, breweries, energy and power companies, textile factories, urban and rural residential areas and research institutes, universities and other places;
Alias of odor online monitoring system:
Electronic nose, odor gas detector, odor gas online monitor, odor online monitoring system, odor electronic nose, odor concentration online monitoring system, odor electronic nose concentration monitoring system, filtered odor detection system, odor OU monitoring system, odor Concentration online monitoring system, odor electronic nose monitoring system, odor concentration electronic nose system, OU value online monitoring system, odor detection analyzer;
2. Product introduction of odor online monitoring system
FT-EC04 odor online monitoring system consists of power supply system, gas collection system, sensor monitoring system, data control system, display and transmission;
The FT-EC04 odor online monitoring system adopts a unique compensation and anti-interference algorithm. The system uses array sensors. In addition to detecting three categories (S series, N series, and VOCs series) in accordance with national standards, the monitoring parameters mainly include ammonia, hydrogen sulfide, and trimethylamine. Amine, carbon disulfide, methyl mercaptan, styrene, methyl sulfide, dimethyl disulfide, single gas and composite odor concentration OU values of 8 kinds of gas substances, a total of nine parameters.
There are four conventional parameters for online monitoring of odor: NH3, H2S, TVOC, and OU value;
Power supply system: Mains power supply conversion system
Gas collection system: The air in the environment is pumped into the gas collection chamber (sniffing bag) through the sampling pump and gas collection rod (including the flow control unit) for detection and analysis;
Monitoring system: gas sensor detection module, meteorological parameter detection module, responsible for the identification and analysis of different odor components in odor samples; sensor array design, integrated multi-gas cross-interference algorithm, temperature and humidity compensation algorithm Control system: the control unit controls each After the sensor detection data is collected, the big data model is used for analysis and calculation to obtain accurate data;
Display system: presents the collected and processed monitoring factor data in an easy-to-understand manner; the chassis is integrated with a 7-inch high-definition color screen, which can be equipped with an external LED display screen or a large-screen control center;
Transmission system: The transmission unit passes DTU or data acquisition instrument (2-channel 232 interface, 3-channel 485 interface, 2-channel Ethernet interface, other interfaces are optional), transmission protocol J212; the data can be displayed on the Ampal Intelligent Environmental Protection Supervision Platform , platforms designated by the demander, Environmental Protection Bureau platforms, etc.;
3. Product features of odor online monitoring system
Gas monitoring parameters: ammonia, hydrogen sulfide, trimethylamine, carbon disulfide, methyl mercaptan, styrene, methyl sulfide, dimethyl disulfide; dimensionless OU value meteorological monitoring parameters: temperature, humidity, wind speed, wind direction, air pressure, Lighting, noise, etc.
product name | Odor online monitoring system | |||||||
Product number | FT-EC04 | |||||||
Sampling method | pump suction | |||||||
Support parameters | Odor monitoring standard parameters | Integration options | ||||||
Ammonia | 0-10ppm | 0.01 ppm | electrochemistry | temperature | -40~120℃ | 0.5℃ | Meteorological integration (ultrasound) | |
hydrogen sulfide | 0-2ppm | 0.001ppm | electrochemistry | humidity | 0.05~100%RH | 0.05%RH | ||
Methyl sulfide | 0-10ppm | 0.01 ppm | electrochemistry | wind direction | 0~359° | 1° | ||
Methyl mercaptan | 0-10ppm | 0.01 ppm | electrochemistry | wind speed | 0~30m/s | 0.1m/s | ||
carbon disulfide | 0-10ppm | 0.01 ppm | electrochemistry | air pressure | 10~1200bmar | 1bmar | ||
dimethyl disulfide | 0-10ppm | 0.01 ppm | electrochemistry | illumination | 0~200klux | 0.1klux | ---- | |
thioether | 0-10ppm | 0.01 ppm | electrochemistry | noise | 20~130dB | 1dB | ---- | |
Styrene | 0-10ppm | 0.001ppm | PID photoion | PM2.5 | 0~1000ug/m3 | 1ug/m3 | laser scattering | |
OU value | 0-100ou | 1ou | Array | PM10 | 0~1000ug/m3 | 1ug/m3 | laser scattering |
Features:
▲Customized design of intelligent modules:
The 9 index target gases including odor OU value, ammonia, hydrogen sulfide, trimethylamine, methyl mercaptan, methyl sulfide, dimethyl disulfide, carbon disulfide, and styrene can be combined in any way, and the technical principles are not limited. The detection range is not limited, and the sensor is pluggable;
At the same time, it supports the monitoring of meteorological parameters, temperature and humidity, wind speed and direction, and atmospheric pressure.
▲Sensor array combination:
Compatible with electrochemical, PID, metal oxide semiconductor and other sensor technology principles Array cross-interference algorithm processing
▲Human-computer interaction interface, real-time display of monitoring data:
Industrial-grade high-definition 7-inch touch screen, monitoring data, change curves, historical data, alarm data and other operating systems can display real-time values, unit values, maximum values, minimum values, and average values of monitoring indicators in real time
Historical data can be queried for any time period and displayed graphically
▲Intelligent sensing technology, automatic identification expansion
Built-in calibrated smart gas sensor, plug and play, automatic recognition; the sensor has an exclusive customized reaction gas chamber, and the target gas can fully and effectively react and detect
By replacing different smart gas sensors, it is possible to detect gases other than the existing four types of gases. One machine has a multi-purpose imported vacuum pump, multiple filter protection devices, and a sniffing bag type to provide stable and steady air flow.
▲Intelligent calibration and multiple data correction modes ensure data stability
Zero-point automatic calibration, intelligent data temperature compensation, K value intelligent algorithm standard gas, target point remote calibration
▲Multiple signal output options available
Ampal provides diversified output methods such as RS485, 232, Ethernet port, USB socket, GPRS and so on.
4. Configuration parameters of odor online monitoring system
Online odor monitoring analyzer configuration parameters | |||||||||
Origin | China | brand | Fengtu Technology | model | FT-EC04 | ||||
serial number | Configuration name | unit | quantity | parameter | |||||
1 | Host | tower | 1 | Test items: ammonia; hydrogen sulfide; methyl mercaptan; methyl sulfide; dimethyl disulfide; carbon disulfide; benzene Ethylene; odor concentration value OU value; | |||||
1.1 | 7 electrochemical sensors 1 PID sensor; | set | 1 | ⑴, 8 8 sensors corresponding to detection: ⑶. Ambient temperature: -20℃-+50℃. ⑷. Environmental humidity: 0-95%RH. ⑸. Detection cycle: The detection cycle and data upload frequency can be set in advance. | |||||
1.2 | Sniffing bag sampling control device | set | 1 | ⑴ Injection flow: 400 ml/min, built-in sampling system. ⑵ Built-in sampling system: 1 built-in pump, four solenoid valves (sampling and zero air). ⑶ 2000ml detachable air bag | |||||
1.3 | Back purge system | set | 1 | 1. Purge gas line control solenoid valve 2. Activated carbon filter | |||||
2 | Data acquisition and transmission instrument | tower | 1 | 1. Output signal: RS232, GPRS, RS485, network port, U disk, etc.; 2. TCP network protocol, 212 protocol, data upload to 4 platforms including Environmental Protection Bureau 3. Remote control, remote setting, GPS positioning function | |||||
3 | Rainproof protective box | tower | 1 | ⑴ Length*width*height: 500*300*600mm ⑵ Material: spray plastic |
5. Configuration parameters of portable odor online monitoring system
Product introduction and application areas
Portable portable composite gas gas detector
(also called portable composite gas analyzer)
It is a high-precision pump-type composite gas analyzer suitable for complex environmental detection. With built-in pre-processing, error compensation, anti-electrical interference, wireless signal output and other functions, the analyzer can detect up to 8 gas types at the same time.
The portable gas detector has built-in optional wireless transmission and can be connected to the Ampal server to realize functions such as remote monitoring, remote setting of alarm values, and remote calibration.
Main purposes and scope of use: Suitable for professional technicians, operators, leaders and other workers.
Project Description | Specific parameters | ||
product name | Portable odor gas detector | ||
Detect gas | Composite gas (NH3, H2S, TVOC, and OU values can be combined at any time, up to 8 types can be analyzed simultaneously) | ||
Measuring range | NH3: 0-2 ppm; H2S: 0-20 ppm TVOC: 0-20 ppm; Odor value: 0-1000 OU (range optional) | ||
Display unit | ppm, mg/m3, %VOL, %LEL (partially switchable) | ||
Resolution | NH3:0.01ppm; H2S:0.01ppm; TVOC:0.001ppm; Odor value: 1 OU | ||
Accuracy | ≤±2%FS | Sampling method | pump suction |
Response time | T90≤20 (electrochemistry); T90≤10 (PID photoionization) | wireless output | LORA, 433M, 800M, GPRS/3G/4G |
Recovery Time | T90≤25(electrochemistry); T90≤10 (Non-dispersive spectroscopic infrared); T90≤30 (catalytic combustion) | Alarm mode | Sound and light alarm; vibration alarm; display character flashing and information reminder, etc. Visual alarm; turning off the alarm is optional |
Drift | ≤±1%FS/year | battery capacity | 3AH large capacity battery, overvoltage and short circuit protection function |
Preprocessing | Built-in dehumidification, dust removal and other pre-processing, suitable for harsh environments such as high humidity and dust | Charging parameters | 5V 1A |
data analysis | With curve waveform analysis data display and data average statistical display | Explosion-proof type | intrinsically safe |
Display method | 5-inch high-definition color touch screen | Number of protection levels | IP65, dustproof, splashproof, and antistatic |
system language | Chinese (default) and English can be switched | Service life | 2 years (sensor), 5 years (instrument) |
Communication Interface | DB9 serial port, USB interface, supports USB hot plug, Can support optional RS232 serial port | data storage | The standard data storage capacity is 300,000 pieces of data, supporting real-time viewing on the machine. Deletion and data export |
shell material | ABS engineering plastic + display table alloy (anti-corrosion and anti-oxidation surface treatment). | size | Overall size: 332×283×148mm |
temperature measurement | -20℃~+500℃ Accuracy ±0.2℃ (with temperature compensation function) | weight | ≥1.5kg |
Humidity measurement | 0~+100%RH accuracy ±3℃ (with temperature compensation function) | Configuration | Instructions, certificate, warranty card, USB charger (including data cable), High-grade ABS engineering plastic box |
6. After-sales service commitment of odor online monitoring system
serial number | After-sales service specific matters | Remark |
1 | We guarantee that the quality, specifications and performance of the products are consistent with those stated in the program documents. | Quality requirements |
2 | We are responsible for the quality of the purchased supporting components and equipment. The material department should conduct strict quality inspections and provide the buyer with product quality certificates and technical documents related to installation and use upon delivery. | Goods delivery for inspection |
3 | During the warranty period, if the equipment fails to work due to its own failure, we will respond within 2 hours after receiving the user's notification and propose a repair plan within 4 hours. | Service within warranty |
4 | After the warranty period, we will continue to provide technical support for the use and operation of the equipment, including troubleshooting and supply of spare parts. Free warranty expires In the next five years, the price of the spare parts we provide is 30% off the market price. | Post-warranty service |
5 | The training we can provide: Hardware installation, use and maintenance training; basic theoretical training on physical properties; instructions on routine sample testing methods, etc. | training content |
6 | We will provide the operation manual, instruction manual, maintenance instructions, etc. of the instrument and equipment to the buyer. | Training materials |
7 | We guarantee that the technical documents provided are clear, complete and accurate, and can be provided in a timely manner to meet the requirements for equipment installation, operation, maintenance and overhaul. | Training materials |
8 | Our technical experts provide guidance and services on the installation and commissioning of the equipment. We are responsible for any losses caused by the supplier's guidance, design, and manufacturing quality during the installation process. If the buyer fails to listen to the guidance of technical experts, the supplier is responsible for replacement and repair, and the cost is borne by the buyer. | Installation cooperation requirements |
9 | Warranty period 1 year | Warranty |
Reasons for purchasing the odor online monitoring system:
1Objective assessment of odor pollutant emissions
For production enterprises, it is inevitable to emit or leak a small amount of odorous pollutants during the production process. By installing an odor online monitoring system, the pollutant emissions can be continuously monitored 24 hours a day, and the over-standard alarm function in the system can be used to It is possible to detect and deal with excessive pollutants in a timely manner; by analyzing real-time data and historical data, we can summarize patterns, identify problems, improve corporate management levels, and ensure that pollutant emissions comply with national standards.
2Response to residents’ complaints
When an odor pollution accident occurs, enterprises that have installed an odor online monitoring system can take timely response measures to reduce the hazards of the accident, give residents a proper explanation, and improve the harmonious relationship between enterprises and residents; the environmental supervision department uses the odor monitoring system to Conduct on-site monitoring of sudden odor pollution accidents, obtain monitoring results immediately, inform enterprises and residents of the pollution situation on-site, and improve the credibility of environmental protection departments.
3 Investigation of pollution sources of odor accidents
Enterprises that have installed an odor online monitoring system can use the odor monitoring data combined with meteorological monitoring data to exclude or determine whether they are pollutants emitted by themselves; the environmental supervision department can use the odor monitoring system to establish a database of characteristic pollutants of enterprises within their jurisdiction. When a pollution accident occurs, polluting enterprises can be quickly identified by combining meteorological data.
4. Improve public image
4.1 Enhance corporate public image and increase brand value
Through the installation of the odor online monitoring system, we can effectively reduce the occurrence of odor pollution accidents, live in harmony with surrounding residents, and respond to the policy of "lucid waters and lush mountains are valuable assets" strongly advocated by the country. Supplemented by appropriate media promotion, it can effectively enhance the corporate image, increase brand value, and can also become a bonus for corporate financing.
4.2 Improve the credibility of environmental protection authorities
The timely handling of odor pollution accidents has always been one of the headaches for environmental protection regulatory authorities. In the past, when there was a lack of effective monitoring methods, residents often mistakenly believed that the competent authorities were inactive and shielding polluting enterprises; while production companies believed that regulatory authorities were stuck in their efforts. Arbitrary fines will have a negative impact on the government's image. Through the use of odor monitoring analyzers, monitoring data can be clearly provided on site, effectively improving the credibility of regulatory authorities.