Meteorological environment monitoring equipment supplier
Insist on doing high-precision customer favorite technology products
1. Overview of Ultrasonic level meter
Ultrasonic level meter adopts the principle of non-contact ultrasonic level measurement to measure liquid level, which is suitable for various liquids and solids.Thank you sincerely for purchasing our Ultrasonic level meter!
This instrument contains a number of patented technologies and has the characteristics of safety, cleanliness, high precision, long life, stability and reliability, easy installation and maintenance, etc. It is suitable for various fields such as acid, alkali, salt, anti-corrosion, high temperature, etc.
This instrument can be connected to a display meter or various DCS systems through 4~20mA or RS485 (Modbus protocol or other customized protocols) to provide real-time material level data for industrial automation operations.
This instrument has the following characteristics:
The circuit design uses high-quality power modules starting from the power supply part, and imported high-stable and reliable components are selected, which can completely replace the same type of foreign imported instruments.
The patented sonic intelligence technology software can perform intelligent echo analysis without any debugging or other special steps. This technology has the functions of dynamic thinking and dynamic analysis.
Our company has patented sonic intelligent technology and adopts automatic temperature compensation. The accuracy of the meter is greatly improved. The material level accuracy reaches 0.8%, and it can resist various interference waves.
This instrument is a non-contact instrument and does not have direct contact with the material body, so the failure rate is low. The instrument provides a variety of installation methods, and users can fully calibrate the instrument through this manual.
All input and output lines of the instrument are protected against lightning and short circuit.
2. Ultrasonic level meter technical indicators
Measuring range: 0~10m (selected based on actual measuring range)
Blind area: 0.25m~0.6m
Ranging accuracy: 0.3% (standard conditions)
Ranging resolution: mm
Pressure: normal pressure
Instrument display: built-in LCD displays material level or spatial distance
Analog output: 4~20mA
Digital output: RS485, Modbus protocol or customized protocol
Power supply voltage: DC24V/AC220V, built-in lightning protection device
Ambient temperature: -20℃~+60℃
Protection level: IP65