Meteorological environment monitoring equipment supplier
Insist on doing high-precision customer favorite technology products
Direct radiation sensor equipment introduction
Direct radiation Sensors are used to measure direct solar radiation, also known as direct normal irradiance (DNI), for solar resource assessment, solar system design, and atmospheric studies.Direct radiation sensor can be used to measure the intensity of direct solar radiation in the spectral range of 0.28-3μm. The core component of the radiation sensor is a high-precision photosensitive element, with an optimized straight barrel design, good stability and high precision. At the same time, a quartz glass sheet made of precision optical cold processing is installed outside the sensing element. The quartz glass sheet is installed at the front end of the barrel. It is equipped with a light hood to effectively prevent environmental factors from affecting the sensor performance; the desiccant locking cover is equipped with a round glass observation window and a built-in color-changing silica gel desiccant, making it easy to observe the water absorption of the desiccant.
This product complies with the technical specifications of ISO9060 and WMO World Meteorological Organization (CIMO Guide) and the latest Chinese meteorological standard "QX/T 20-2016 Pyranometer". It can be widely used in the measurement of direct solar radiation energy in departments such as meteorology, solar energy utilization, agriculture and forestry, aging of building materials, and atmospheric environment monitoring.
Direct radiation sensor technical parameters
Parameter name | Specifications | illustrate |
grade standards | FIRST CLASS | |
Time response (95%) | 10s | |
Thermal radiation zero offset | ±2W/㎡ | |
Temperature change zero point offset | ±1W/㎡ | |
nonlinear error | ±0.2% | |
annual stability | ±0.5%/1yr | |
Spectral consistency | ±3% | |
Spectral error | ±0.2% | |
Temperature response (-10~40℃) | ±0.5% | |
tilt error | ±0.2% | |
Spectral response | 285~3000nm | |
open corner | 4° | |
Tracking accuracy | <±1º/24h | |
Sensitivity | 7~14μV/W•m-2 | |
Working voltage | none | Millivolt voltage output |
DC24V | Standard current output | |
DC 12~24V | RS485 output | |
Signal output | 0~20mV | |
4~20mA | ||
RS485 (MODBUS protocol) | ||
Cable length | 2 meters | |
working environment | Temperature range: -40~85℃ | |
Humidity range: 0~100% RH | ||
weight | 0.46kg | Cable not included |
Overall dimensions | 290×67×56 (mm) | |
Installation dimensions | 4-M2.5, hole spacing 23×86 (mm) |
Direct radiation sensor appearance and composition