Home>Products>Intelligent atmosphere>Odor gas detector>Odor gas online monitoring system
Odor gas online monitoring system

Odor gas online monitoring system

Model:FT-EC04
Brand:fengtu
Odor gas online monitoring system is specifically designed for places that are prone to odors, such as garbage disposal, sewage stations, fixed pollution sources, chemical parks, and factory boundaries....

1.Introduction to Odor gas online monitoring system

Odor gas online monitoring system is specifically designed for places that are prone to odors, such as garbage disposal, sewage stations, fixed pollution sources, chemical parks, and factory boundaries.The Odor gas online monitoring system is based on our company's many years of experience in gas detection and atmospheric environment monitoring.In accordance with the "Odor Pollutant Emission Standards (GB14554-1993)" and "Odor Pollution Environmental Monitoring Technical Specifications (HJ905-2017)", it is specially designed for those who are prone to odors.In this place, we independently developed and produced an online odor concentration monitoring system, commonly known as the odor electronic nose;

The concept of stench:

Odor refers to all gaseous substances that stimulate the olfactory organs, cause people's discomfort and damage the living environment.There are many types of them.So far, there are more than 4,000 types that can be sensed by the human sense of smell, among which dozens of types are more harmful to human health.;

Scenes where the stench appears:

Science and technology parks, chemical parks, landfills, garbage treatment stations, waste power plants, waste incineration sites, chemical plants, breeding farms, sewage treatment plants, pharmaceutical factories, breweries, energy and power companies, textile factories, urban and rural residential areas and research institutes, universities and other places;

Odor gas online monitoring system alias:

Electronic nose, odor gas detector, odor gas online monitor, odor gas online monitoring system, odor electronic nose, odor concentration online monitoring system, odor electronic nose concentration monitoring system, filtered odor detection system, odor OU monitoring system, odor electronic nose Gas concentration online monitoring system, odor electronic nose monitoring system, odor concentration electronic nose system, OU value online monitoring system, odor detection analyzer;

2.Product introduction of Odor gas online monitoring system

Odor gas online monitoring system consists of power supply system, gas gathering system, sensor monitoring system, data control system, display and transmission;

The Odor gas online monitoring system adopts a unique compensation and anti-interference algorithm.In addition to detecting three categories (S series, N series, VOCs series) in accordance with national standards, the system uses array sensors.The monitoring parameters mainly include ammonia, hydrogen sulfide, trimethylamine, Carbon disulfide, methyl mercaptan, styrene, methyl sulfide, dimethyl disulfide, single gas and composite odor concentration OU values of 8 gas substances, a total of nine parameters.

There are four conventional parameters for online monitoring of odor: NH3, H2S, TVOC, and OU value;

Power supply system: Mains power supply conversion system

Gas collection system: The air in the environment is pumped into the gas collection chamber (sniffing bag) through the sampling pump and gas collection rod (including the flow control unit) for detection and analysis;

Monitoring system: gas sensor detection module, meteorological parameter detection module, responsible for the identification and analysis of different odor components in odor samples; sensor array design, integrated multi-gas cross-interference algorithm, temperature and humidity compensation algorithm Control system: the control unit controls each After the sensor detection data is collected, the big data model is used for analysis and calculation to obtain accurate data;

Display system: presents the collected and processed monitoring factor data in an easy-to-understand manner; the chassis is integrated with a 7-inch high-definition color screen, which can be equipped with an external LED display screen or a large-screen control center;

Transmission system: The transmission unit passes DTU or data acquisition instrument (2 channels 232 interface, 3 channels 485 interface, 2 channels Ethernet interface, other interfaces are optional), transmission protocol J212; the data can be displayed on the smart environmental protection supervision platform, as required Party designated platform, Environmental Protection Bureau platform, etc.;

Odor gas online monitoring system

3.Product features of Odor gas online monitoring system

Gas monitoring parameters: ammonia, hydrogen sulfide, trimethylamine, carbon disulfide, methyl mercaptan, styrene, methyl sulfide, dimethyl disulfide; dimensionless OU value meteorological monitoring parameters: temperature, humidity, wind speed, wind direction, air pressure, Lighting, noise, etc.

Product name

Odor gas online monitoring system

Product model FT-EC04
Sampling method

pump suction

Support parameters

Odor monitoring standard parameters Integration options
Ammonia 0-10ppm 0.01ppm electrochemistry temperature -40~120℃ 0.5℃ Meteorological integration (ultrasound)
hydrogen sulfide 0-2ppm 0.001ppm electrochemistry humidity 0.05~100%RH 0.05%RH
Methyl sulfide 0-10ppm 0.01ppm electrochemistry wind direction 0~359°
Methyl mercaptan 0-10ppm 0.01ppm electrochemistry wind speed 0~30m/s 0.1m/s
carbon disulfide 0-10ppm 0.01ppm electrochemistry air pressure 10~1200bmar 1bmar
dimethyl disulfide 0-10ppm 0.01ppm electrochemistry illumination 0~200klux 0.1klux ----
thioether 0-10ppm 0.01ppm electrochemistry noise 20~130dB 1dB ----
Styrene 0-10ppm 0.001ppm PID photoion PM2.5 0~1000ug/m3 1ug/m3 laser scattering
OU value 0-100ou 1ou Array PM10 0~1000ug/m3 1ug/m3 laser scattering

Features:

▲Customized design of intelligent modules:

Any combination of 9 index target gases including odor OU value, ammonia, hydrogen sulfide, trimethylamine, methyl mercaptan, methyl sulfide, dimethyl disulfide, carbon disulfide, and styrene can be made, and the technical principles are not limited.The detection range is not limited, and the sensor is pluggable;

At the same time, it supports the monitoring of meteorological parameters, temperature and humidity, wind speed and direction, and atmospheric pressure.

▲Sensor array combination:

Compatible with electrochemical, PID, metal oxide semiconductor and other sensor technology principles Array cross-interference algorithm processing

▲Human-computer interaction interface, real-time display of monitoring data:

Industrial-grade high-definition 7-inch touch screen, monitoring data, change curves, historical data, alarm data and other operating systems can display real-time values, unit values, maximum values, minimum values, and average values of monitoring indicators in real time

Historical data can be queried for any time period and displayed graphically

▲Intelligent sensing technology, automatic identification expansion

Built-in calibrated smart gas sensor, plug and play, automatic recognition; the sensor has an exclusive customized reaction gas chamber, and the target gas can fully and effectively react and detect

By replacing different smart gas sensors, gases other than the existing four types of gases can be detected.One machine has a multi-purpose imported vacuum pump, multiple filter protection devices, and a sniffing bag type to provide stable and smooth air flow.

▲Intelligent calibration and multiple data correction modes ensure data stability

Zero-point automatic calibration, intelligent data temperature compensation, K value intelligent algorithm standard gas, target point remote calibration

▲Multiple signal output options available

Provides diversified output methods such as RS485, 232, Ethernet port, USB port, GPRS, etc.

4.Odor gas online monitoring system configuration parameters

Online odor monitoring analyzer configuration parameters
Origin China brand Fengtu Technology model FT-EC04
serial number Configuration name unit quantity parameter
1 Host tower 1 Test items: ammonia; hydrogen sulfide; methyl mercaptan; methyl sulfide; dimethyl disulfide; carbon disulfide; styrene; odor concentration value OU value;
1.1 7 electrochemical sensors, 1 PID sensor; set 1 ⑴.Eight 8 sensors respectively detect: ⑶.Ambient temperature: -20℃-+50℃.⑷.Environmental humidity: 0-95%RH.⑸.Detection cycle: The detection cycle and data upload frequency can be set in advance.
1.2 Sniffing bag sampling control device set 1 ⑴ Injection flow: 400 ml/min, built-in sampling system.⑵ Built-in sampling system: 1 built-in pump, four solenoid valves (sampling and zero air).⑶ 2000ml detachable air bag
1.3 Back purge system set 1 1.Purge gas line control solenoid valve 2.Activated carbon filter
2 Data acquisition and transmission instrument tower 1 1.Output signal: RS232, GPRS, RS485, network port, U disk, etc.; 2.TCP network protocol, 212 protocol, data upload to 4 platforms including Environmental Protection Bureau 3.Remote control, remote setting, GPS positioning function
3 Rainproof protective box tower 1 ⑴ Length*width*height: 500*300*600mm ⑵ Material: spray plastic

5.Odor gas online monitoring system configuration parameters

Odor gas online monitoring system configuration parameters


Product introduction and application fields

Portable portable composite gas gas detector

(also called portable composite gas analyzer)

It is a high-precision pump-type composite gas analyzer suitable for complex environmental detection.With built-in pre-processing, error compensation, anti-electrical interference, wireless signal output and other functions, the analyzer can detect up to 8 gas types at the same time.

The portable gas detector has built-in optional wireless transmission and can be connected to the Ampal server to realize functions such as remote monitoring, remote setting of alarm values, and remote calibration.

Main purposes and scope of use: Suitable for professional technicians, operators, leaders and other workers.

Project content Specific parameters
Product name Portable odor gas detector
Detect gas Composite gas (NH3, H2S, TVOC, and OU values can be combined at will, up to 8 types can be analyzed simultaneously)
Measuring range NH3: 0-2ppm; H2S: 0-20ppm TVOC: 0-20ppm; Odor value: 0-1000OU (range optional)
Display unit ppm, mg/m3, %VOL, %LEL (partially switchable)
resolution NH3:0.01ppm; H2S:0.01ppm; TVOC:0.001ppm; Odor value: 1 OU
Accuracy ≤±2%FS Sampling method pump suction
response time T90≤20 (electrochemistry); T90≤10 (PID photoionization) wireless output LORA, 433M, 800M, GPRS/3G/4G
recovery time T90≤25 (electrochemistry); T90≤10 (non-dispersive spectroscopic infrared); T90≤30 (catalytic combustion) Alarm mode Sound and light alarm; vibration alarm; display character flashing and information reminder, etc.Visual alarm; turning off the alarm is optional
Drift ≤±1%FS/year battery capacity 3AH large capacity battery, overvoltage and short circuit protection function
preprocessing Built-in dehumidification, dust removal and other pre-processing, suitable for harsh environments such as high humidity and dust Charging parameters 5V 1A
data analysis With curve waveform analysis data display and data average statistical display Explosion-proof type intrinsically safe
Display mode 5-inch high-definition color touch screen Number of protection levels IP65, dustproof, splashproof, and antistatic
system language Chinese (default) and English can be switched Service life 2 years (sensor), 5 years (instrument)
Communication interface DB9 serial port, USB interface, supports USB hot plug, optional RS232 serial port data storage The data storage has a standard data capacity of 300,000 pieces and supports local real-time viewing, deletion and data export.
Shell material ABS engineering plastic + display table alloy (anti-corrosion and anti-oxidation surface treatment). size Overall size: 332×283×148mm
temperature measurement -20℃~+500℃, accuracy ±0.2℃ (with temperature compensation function) weight ≥1.5kg
Humidity measurement 0~+100%RH, accuracy ±3℃ (with temperature compensation function) Configuration Instructions, certificate, warranty card, USB charger (including data cable), high-end ABS engineering plastic box

6.After-sales service commitment

serial number After-sales service specific matters Remark
1 We guarantee that the quality, specifications and performance of the products are consistent with those stated in the program documents. Quality requirements
2 We are responsible for the quality of the purchased supporting components and equipment.The material department should conduct strict quality inspections and provide the buyer with product quality certificates and technical documents related to installation and use upon delivery. Goods delivery for inspection
3 During the warranty period, if the equipment fails to work due to its own failure, we will respond within 2 hours after receiving the user's notification and propose a repair plan within 4 hours. Service within warranty
4 After the warranty period, we will continue to provide technical support for the use and operation of the equipment, including troubleshooting and supply of spare parts.Within five years after the expiration of the free warranty period, the price of spare parts provided by us is 30% off the market price. Post-warranty service
5 The training we can provide: Hardware installation, use and maintenance training; basic theoretical training on physical properties; instructions on routine sample testing methods, etc. Training content
6 We will provide the operation manual, instruction manual, maintenance instructions, etc.of the instrument and equipment to the buyer. training materials
7 We guarantee that the technical documents provided are clear, complete and accurate, and can be provided in a timely manner to meet the requirements for equipment installation, operation, maintenance and overhaul. training materials
8 Our technical experts provide guidance and services on the installation and commissioning of the equipment.We are responsible for any losses caused by the supplier's guidance, design, and manufacturing quality during the installation process.If the buyer fails to listen to the guidance of technical experts, the supplier is responsible for replacement and repair, and the cost is borne by the buyer. Installation cooperation requirements
9 Warranty period 1 year Warranty period

Reasons for purchasing Odor gas online monitoring system:

1Objective assessment of odor pollutant emissions

For production enterprises, it is inevitable to discharge or leak a small amount of odorous pollutants during the production process.By installing the Odor gas online monitoring system, the pollutant emissions can be continuously monitored 24 hours a day and the over-standard alarm function in the system can be used., can promptly discover and deal with excessive pollutants; by analyzing real-time data and historical data, summarize patterns, identify problems, improve corporate management levels, and ensure that pollutant emissions comply with national standards.

2Response to residents’ complaints

When an odor pollution accident occurs, companies that have installed the Odor gas online monitoring system can take timely response measures to reduce the hazards of the accident, give residents a proper explanation, and improve the harmonious relationship between the company and residents; the environmental supervision department uses the odor monitoring system to , conduct on-site monitoring of sudden odor pollution accidents, obtain monitoring results immediately, inform enterprises and residents of the pollution situation on-site, and improve the credibility of the environmental protection department.

3 Investigation of pollution sources of odor accidents

Enterprises that have installed the Odor gas online monitoring system can use odor monitoring data combined with meteorological monitoring data to exclude or determine whether they are pollutants emitted by themselves; environmental supervision departments can use the odor monitoring system to establish a database of characteristic pollutants of enterprises within their jurisdiction.When an odor pollution accident occurs, the polluting enterprises can be quickly identified based on meteorological data.

4.Improve public image

4.1 Enhance corporate public image and increase brand value

Through the installation of Odor gas online monitoring system, we can effectively reduce the occurrence of odor pollution accidents, live in harmony with surrounding residents, and respond to the policy of "lucid waters and lush mountains are valuable assets" strongly advocated by the country.Supplemented by appropriate media promotion, it can effectively enhance the corporate image, increase brand value, and can also become a bonus for corporate financing.

4.2 Improve the credibility of environmental protection authorities

The timely handling of odor pollution accidents has always been one of the headaches for environmental protection regulatory authorities.In the past, when there was a lack of effective monitoring methods, residents often mistakenly believed that the competent authorities were inactive and shielding polluting enterprises; while production companies believed that the regulatory authorities were stuck.Arbitrary fines will have a negative impact on the government's image.Through the use of odor monitoring analyzers, monitoring data can be clearly provided on site, effectively improving the credibility of regulatory authorities.