1.Functional requirements of Odor Online Monitoring System

Odor Online Monitoring System is specifically designed for places that are prone to odors, such as garbage disposal, sewage stations, stationary pollution sources, and factory boundaries.Intermittent monitoring or continuous 24-hour environmental odor monitoring for polluted areas.Standard monitoring indicators can simultaneously achieve the types of pollutant control specified in the GB14554 standard: odor concentration OU value, ammonia, styrene, hydrogen sulfide, VOCS, trimethylamine , methyl sulfide, methyl mercaptan, dimethyl disulfide, carbon disulfide.

2.Odor Online Monitoring System detection part

The monitoring system is composed of a variety of sensor hybrid arrays.The sensor types include metal oxide sensors, PID photoion detectors, electrochemical sensors, and ETO sensors.

Each sensor can be individually plugged and unplugged, and can be individually calibrated and replaced.

The instrument and equipment calibration operation function is available on-site, so there is no need to take it back to the laboratory for calibration.

When using a multi-sensor array layout, a working analysis curve that conforms to the artificial olfactory identification method should be established to simulate the human olfactory system.

3.Odor Online Monitoring System display control system

The 7-inch true color LCD touch screen is selected to display all real-time monitoring data and the system working status.

This machine can display historical concentration curves, directly display data changes and component proportions in the form of charts, and conduct real-time data analysis, which is helpful for event judgment.

Built-in parameter setting and sensor pre-maintenance function can remind customers to perform sensor maintenance in time.

The data record can reach at least 1,000,000 items, with built-in database and USB data copying capability.

The analyzer's firmware can be easily upgraded via a USB flash drive.The system can also perform remote one-click upgrade, parameter configuration modification and other functions.

4.Odor Online Monitoring System communication system

The IoT access server adopts a professional communication SOC processor, dual-core and four threads, with a main frequency of up to 880MHz and a large-capacity Flash as standard.Based on the powerful hardware platform, feature-rich software can be implemented to meet diverse monitoring applications.The deeply customized JYun operating system supports GPRS, RJ45, ZigBee, LoRa, WIFI, NB-IOT and other communication methods.Flexible networking and secure data transmission.The motherboard and components comply with industrial-grade standards, support a wide voltage input of 9~36V, and the ambient temperature range can reach -20~65℃.

Supports Modbus communication protocol, which can set up and communicate with the system.Data can be transmitted via 4G wireless or wired 485, and monitoring data can be viewed in real time through a computer web page or mobile APP.

Support cloud data storage.And it can realize the concurrent transmission function of multiple servers, and can support direct upload to up to 3 platforms.The analyzer supports the HJ212-2017 network protocol and the connection with the data management platform.

The system software has functions such as direct data transmission, data storage, statistical analysis, over-standard alarm, and point writing.

5.Odor Online Monitoring System preprocessing part

It has insect and large particle filtration, dust filtration and water vapor filtration to effectively filter oil, gas, water vapor, dust, etc.in the sample gas, effectively reducing interference during the monitoring process, and is faster, more efficient, and more accurate.The unique gas circuit design effectively solves the problem of gas sensor gap.interference to ensure that the sensor works in a steady-state environment.

6.Odor Online Monitoring System chassis part

Pole manufacturing process: Equipped with lightning rods and grounding: The top of the pole is equipped with lightning rods.The segmented combination method facilitates logistics and transportation.

The entire chassis is sprayed with outdoor plastic powder and molded at 180° high temperature.The coating has excellent appearance quality and much higher corrosion and wear resistance.The overall appearance is stable, generous, thick, and has high load-bearing strength, which solves the problem of serious pole shaking in strong winds and other bad weather.Waterproof grade IP53 or above, safe for use in outdoor environments.

7.Odor Online Monitoring System sensor parameters

1.H2S technical parameters

principleElectrochemistry (imported sensor)
Measuring range0-20PPM
Indication error≤±10%
Repeatability≤2%
response time≤50S
zero drift≤±2%FS
Range drift≤±3%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

2.NH3 technical parameters

principleElectrochemistry (imported sensor)
Measuring range0-50PPM
Indication error≤±10%
Repeatability≤3%
response time≤120S
zero drift≤±2%FS
Range drift≤±3%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

3.CH4S technical parameters

principleElectrochemistry (imported sensor)
Measuring range0-20PPM
Indication error≤±10%FS
Repeatability≤3%
response time≤120S
zero drift≤±5%FS
Range drift≤±5%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

4.C2H6S technical parameters

principleElectrochemistry (imported sensor)
Measuring range0-20PPM
Indication error≤±10%FS
Repeatability≤3%
response time≤80S
zero drift≤±5%FS
Range drift≤±5%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

5.C2H6S2 technical parameters

principleElectrochemistry (imported sensor)
Measuring range0-20PPM
Indication error≤±10%FS
Repeatability≤3%
response time≤120S
zero drift≤±5%FS
Range drift≤±5%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

6.CS2 technical parameters

principleElectrochemistry (imported sensor)
Measuring range0-20PPM
Indication error≤±10%FS
Repeatability≤3%
response time≤120S
zero drift≤±5%FS
Range drift≤±5%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

7.C8H8 technical parameters

principlePID (imported sensor)
Measuring range0-20PPM
Indication error≤±10%FS
Repeatability≤3%
response time≤20S
zero drift≤±5%FS
Range drift≤±5%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

8.C3H9N technical parameters

principleElectrochemistry (imported sensor)
Measuring range0-20PPM
Indication error≤±10%FS
Repeatability≤3%
response time≤120S
zero drift≤±5%FS
Range drift≤±5%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

9.OU technical parameters

principleMOS (imported sensor)
Measuring range0-1000%OU
Indication error≤±10%FS
Repeatability≤3%
response time≤20S
zero drift≤±3%FS
Range drift≤±5%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W

10.Particulate matter parameters (optional)

principleLaser scattering/dust meter (with cutter)
Measuring range0-30mg/m³/0-2000mg/m³

11.VOC technical parameters (optional)

principlePID (imported sensor)
Measuring range0-20PPM
Indication error≤±10%FS
Repeatability≤3%
response time≤20S
zero drift≤±5%FS
Range drift≤±5%FS
temperature-20℃~+55℃
power supplyDC 12V±20%
Power consumption<1W