Meteorological environment monitoring equipment supplier
Insist on doing high-precision customer favorite technology products
1.Introduction to string power supply products
The string power supply is also called the string EL test power supply. The string power supply is easy to operate and portable. It can complete the synchronous power-on of the entire string and the detection is faster. It is suitable for photovoltaic power station full inspection projects and water surfaces, roofs, and factory buildings. , mountainous and other photovoltaic power station testing. The string power supply is developed by our company based on the reverse power-up characteristics of photovoltaic power station strings. It converts alternating current into direct current and inputs it into the panel to stimulate electroluminescence, thereby testing the internal defects of EL.
FT-150050 is a research and development program-controlled power supply that controls the electrical performance and safeguard measures of the string power supply through the program software system. Its pro version is configured with high-quality software, using higher-quality imported electronic components and an open programming host to better ensure the stability and safety of string detection.
2. Technical parameters of string power supply
1. EL string power supply for photovoltaic use
Specification | FT-150030 | FT-150050 | FT-150010 |
Electric energy parameters | 0~1500V; 0~3A | 0~1500V; 0~5A | 0~1500V; 0~10A |
quality | Programmable linear domestic | Program-controlled custom import | Program-controlled custom import |
Scenes | EL detector single block/string test | EL detector single block/string test | EL detector + drone EL test |
Voltage output | 0~1500V | 0~1500V | 0~1500V |
Voltage accuracy | 1V | 0.001V | 0.001V |
Compensation voltage | 12V | 96V | 96V |
Current output | 0~3A | 0~5A | 0~10A |
Current accuracy | 0.1A | 0.001A | 0.001A |
Power accuracy | ±0.1A;±1V | ±0.001A; ±0.001V | ±0.001A; ±0.001V |
Power output | 0~4.5KW | 0~8KW | 0~16KW |
Power stability | ±0.1% | ±0.002% | ±0.002% |
Output accuracy | ±0.1% | ±0.001% | ±0.001% |
Output efficiency | >80% | >95% | >95% |
Output linear regulation rate | ±0.5% | ±0.005% | ±0.005% |
Output load regulation | ±0.5% | ±0.005% | ±0.005% |
Input voltage | 220VAC | 380VAC | 380VAC |
input frequency | 50/60Hz | 50/80Hz | 50/100Hz |
Input power factor | >0.75 | >0.5 | >0.5 |
Power on time | Manual control | Program-controlled scheduled automatic power-on and automatic power-off | |
Insulation withstand voltage input to output | 2500VDC | ||
Insulation withstand voltage output to shell | 500VDC | ||
OVP adjustment range | 0-100% front panel adjustment (or digital interface) | ||
OVP adjustment accuracy | ±1% of nominal value |
2. EL string power supply/programmable control system
Specification | FT-150030 | FT-150050 | FT-150010 |
Programmable control system | Control current and voltage output and monitor power supply working status | The program control panel can directly set various program control indicators of the power supply. | |
Programmable remote interface | RS-485C, analog interface (0-10V) | ||
Program control panel | - | The power panel can be programmed to control power on and off times, scheduled power on, protection thresholds, etc. | |
Reverse current protection | - | The reverse current impedance threshold can be set to prevent string current backflow. | |
Short circuit protection | Photovoltaic string reverse connection short circuit protection to prevent photovoltaic modules from diode breakdown | ||
Programmable buffer protection | - | Cache-type photovoltaic groups are connected and powered off in series to prevent large currents from penetrating the photovoltaic panels. | |
Programmable steady-state output | - | Adaptively matches current and voltage according to different power components in the string (to avoid breakdown of component diodes) | |
Digital voltage programming accuracy | - | ±0.001% | ±0.001% |
Digital current programming accuracy | - | ±0.001% | ±0.001% |
Programmable rise time | - | 0~10s can be set | |
Programmable fall time | - | 60ms (no load); 250ms (10% load); 2.5s (full load) | |
Voltage fluctuation control | 0.1V/ms~10V/ms | 0.001V/ms~0.002V/ms | |
Current fluctuation control | 0.1A~0.2A | 0.001A~0.01A, or 1NF | |
Fluctuation control minimum time | 5ms | 0.1ms | |
Panel display | Digital display insulated control panel | Host program control panel | |
Panel control | - | The power supply current and voltage protection limit value OVP can be set | |
Photovoltaic EL power-on characteristics | High and low current switching test (manual switching) | High and low current switching test (automatic switching by program) | |
Number of components powered on simultaneously | Can simultaneously complete the detection of power supply access for 1 to 32 photovoltaic panels (within 1500V) | ||
Photovoltaic power access port | Combiner box/inverter/string port/module port | ||
Steady state output module | - | Stable power supply ensures uniform electrical energy parameters of each component in the string (to prevent photovoltaic panel breakdown) | |
Thermostatic control module | Air cooling continuous heat dissipation and temperature control | Programmable electronic temperature control of 45°C ensures 24-hour uninterrupted work | |
Overload protection | - | The overload threshold can be set, and the output will automatically stop when overloaded to prevent the power supply circuit breaker transformer from being burned. | |
Output short circuit automatic protection | Protects power failure and personal danger caused by power station line or component string breakage, and the power supply automatically cuts off the power | ||
Input voltage automatic protection | - | Protects power components from burning due to excessive input voltage fluctuations | |
Phase loss protection | Can protect power supply damage and accidents caused by three-phase open circuit | ||
Internal overheating protection | Dynamic heat dissipation according to the internal temperature ensures that the power supply will not be burned due to excessive temperature. | ||
High voltage isolation protection | Ensure the safety of operators working with high-voltage electricity on the shell and panel of the machine | ||
input line | 2 meters (6 square meters) | ||
Wiring | AC220 | Three-phase three-wire + ground wire | |
volume and weight | 430x88x450mm; 13kg | 17kg | 26kg |
Note: The string power supply is a high-power DC output power supply, which is high-voltage equipment. The program control system is customized for photovoltaic power station scenarios, which can better ensure the safety of manual construction on site. However, high-voltage equipment is still high-risk and high-risk equipment. Please strictly follow the operating instructions and standardize wiring and operation. If the power supply is protected, contact the manufacturer as soon as possible to solve the problem. Do not perform wiring operations without authorization to prevent danger! ! !