Meteorological environment monitoring equipment supplier
Insist on doing high-precision customer favorite technology products
Optical time domain reflectometer product review
Optical time domain reflectometer Used to measure the length, loss, and connection quality of various optical fibers and cables.The 6426AOptical time domain reflectometer is a 7-inch capacitive full touch screen that integrates automatic OTDR, expert OTDR, event map, optical power meter (OPM), visual red light fault location (VFL), stable light source (LS), multi-core test, loss Test functions.The maximum dynamic range of OTDR is 28dB, which can achieve accurate testing up to 100km, the minimum event blind zone is 3m, and the sampling resolution is up to 2.5cm.Equipped with a 4600mAh high-density and large-capacity polymer lithium battery, it has intelligent power-saving management and supports power bank power supply and charging.
6426A is used to measure the length, loss, connection quality and other parameters of various types of optical fiber cables.It is widely used in the engineering construction, line maintenance and emergency repair testing of fiber-to-the-home, metropolitan area networks and secondary backbone network communication systems, and the development of optical fiber cables.and production measurement and other fields.
Main features of Optical time domain reflectometer
The 7-inch large touch screen brings silky-smooth operation and comfortable visual experience;
28dB dynamic range, easily test 100km optical fiber lines;
One-click automatic testing, automatic parameter configuration, automatic event analysis, and easy viewing of fault events;
Automatic photoeye map, graphic display of fault events, and fault information clearly visible;
OPM, red light, stable light source and other multi-functions are integrated to protect your engineering operations;
With light testing, you can easily control fiber-to-the-home scenarios and easily locate fault points in fiber lines;
Supports Bellcore GR196 and SR-4731 file formats;
The light source supports continuous/modulated mode output;
4600mA ultra-large capacity battery, ultra-long battery life, to meet your work needs all day long.
Fast automated testing
The automatic test function eliminates the need for users to know more details about the operation of the instrument.The test steps become very simple.You only need to enter "Automatic OTDR", connect the optical fiber to the corresponding OTDR port of the product, and click the [Automatic Test] button.The instrument will automatically set the corresponding test conditions and give the final test results, including test curves and event lists.
Automatic light monitoring and alarm function
When an OTDR tests an optical fiber link, if there is a communication optical signal in the optical fiber, the test results will be inaccurate and even cause irreparable damage to the detector inside the instrument.6426A has the function of automatically monitoring the communication optical signal in the optical fiber under test.As long as the optical fiber under test is connected to the optical interface of the product, it will automatically sense and monitor whether there is communication optical signal in the optical fiber during the test phase.Once the optical signal is detected, it will be detected in time.Prompts alarm information to provide timely protection for the instrument.
Optical time domain reflectometer technical specifications
project | 6426A |
Working wavelength | 1310/1550/1625/1650±20nm |
Maximum dynamic range | 28dB |
event blind spot | 3m |
Ranging accuracy | ±(0.75+distance×0.0025%+sampling interval)m, excluding refractive index error |
Ranging resolution | 0.025, 0.05, 0.1, 0.2, 0.5, 1, 2, 4, 8, 16, 32m |
Test range | 0.4, 0.8, 1.6, 3.2, 6.4, 16, 32, 64, 128, 256, 512km |
Test pulse width | 5, 10, 30, 80, 160, 320, 640, 1280, 5120, 10240, 20480ns |
Maximum number of sampling points | 256k |
linearity | 0.03dB/dB |
loss resolution | 0.001dB |
Refractive index setting range | 1.00000~1.99999 (step size 0.00001) |
distance unit | Kilometers, meters, thousand feet, feet |
show | 800×480, 7-inch TFT color LCD (capacitive touch screen) |
Optical output interface | FC/UPC (standard, SC/UPC optional) |
interface language | Available in Simplified Chinese and English (other language support available) |
external interface | USB Type C, Micro SD |
power supply | AC/DC adapter; input: AC100V~240V, 50/60Hz; output: DC/5V/2A; internal lithium battery: 3.7V, 4600mAh |
Battery working time | Low brightness, standby ≥6h |
Dimensions | Width × height × depth ≤ 200mm × 150mm × 38mm (excluding soft glue) |
weight | ≤700g (including battery) |
environmental adaptability | Working temperature: 0℃~+40℃ (battery charging: 5℃~40℃); storage temperature: -20℃~+60℃ (battery: -20℃~60℃); relative humidity: 5%~95%, No condensation |
VFL (standard configuration)
Working wavelength: 650nm±20nm
Output power: 2mW (typical)
Optical power meter (standard configuration)
Wavelength range: 850nm~1650nm
Power range: -60dBm~+3dBm
Stable light source (standard configuration)
Working wavelength: same as OTDR working wavelength
Output power: ≥-5dBm
6426A OTDR standard module technical specifications
Single wavelength module:
module number | Working wavelength | wavelength | Dynamic range 1(dB) | Event blind area 2 (m) | Attenuation blind zone 3 (m) |
6426A-1101 | Single mode 1625nm | single wavelength | 28 | 3.0 | 8.0 |
6426A-1102 | Single mode 1650nm | 28 | 3.0 | 8.0 |
Dual wavelength module:
module number | Working wavelength | wavelength | Dynamic range 1(dB) | Event blind area 2 (m) | Attenuation blind zone 3 (m) |
6426A-2101 | Single mode 1310/1550nm | dual wavelength | 28/26 | 3.0 | 8.0 |
6426A-2102 | Single mode 1310/1550nm | 26/24 | 3.0 | 8.0 | |
6426A-2103 | Single mode 1310/1550nm | 24/22 | 3.0 | 8.0 |
Note:
1.The ambient temperature is 23℃±5℃, the maximum test pulse width, the average time is greater than 180s, and SNR=1;
2.Measuring range ≤1.6km, pulse width 5ns, fiber end face reflection loss ≥40dB, typical value;
3.Measuring range ≤1.6km, pulse width 5ns or less, fiber end face reflection loss ≥50dB, typical value.
Ordering information
Host: 6426A Optical time domain reflectometer
Standard configuration:
serial number | name | illustrate |
1 | 6426AOptical time domain reflectometer | Contains lithium battery |
2 | power cord assembly | Input: AC100V~240V, 50/60Hz; Output: DC/5V/2A |
3 | TF card | Capacity 32G, loaded inside the instrument, including analysis software |
4 | User Manual | - |
5 | Product certificate | - |
6 | Special soft bag | - |
Optional accessories:
Option number | name | illustrate |
6426A-001 | SC adapter | - |
6426A-002 | ST adapter | - |
Purchase information:
Note: Due to the need for design improvement, the above content is subject to change without prior notice.